TDR guided radar level measurement
(Buffer) Tank with internal heating/cooling system
Contact level measurement of liquids or liquid-liquid interfaces.
Possible guided radar devices for this application
OPTIFLEX 7200
- Continuous level and interface measurement in process or storage tanks, reactors and pressure vessels
- Extensive choice of probes for harsh process conditions
- Measuring range: 0.3…60 m / 1…197 ft
- -50…+250°C / -58…+482°F; -1…100 barg / -14.5…1450 psig
OPTIFLEX 8200
- Continuous level and interface measurement in reactors and separators
- Single or double ceramic process seal system for demanding process conditions
- Measuring range: 0.6…60 m / 2…197 ft
- -50…+315°C; -58…+599°F; -1…320 barg; -14.5…4641 psig
Accessories for this product
OPTISWITCH 5300
Vibration level switch for heavy-duty applications
- Point level detection of liquids under extreme conditions
- Probe length: up to 3000 mm / 118 ft
- ≥0.47 g/cm3 / 0.017 lb/in3 (optional: ≥0.42 g/cm3 or 0.015 lb/in3)
- -196…+450°C / -321…+842°F; -1…160 barg / -14.5…2321 psig
OPTISWITCH 5200
Vibration level switch with rigid extension for process applications
- Point level detection of liquids
- Probe length up to 6000 mm / 236"
- Density: ≥0.5 g/cm3 / 0.018 lb/in3
- -50…+250°C / -58…+482°F; -1…64 barg / -14.5…925 psig
OPTISWITCH 5250
Vibration level switch with rigid extension for hygienic applications
- Point level detection of liquids in the food, beverage and pharmaceutical industry
- Probe length: up to 6000 mm / 236"
- Density: ≥0.5 g/cm3 / 0.018 lb/in3
- -50…+250°C / -58…+482°F; -1…64 barg / -14.5…928 psig